Performance Description:
- Model G4-68,Y4-68 boiler ventilator and blower apply to the system of ventilator and blower for vapor boiler below 230T/H in the power plant.While having no special requirement,G4-68 may also be used for mine ventilation and ordinary ventilation.
The medium conveyed by the ventilator is air,no more than 80ºC of the highest temperature.The medium conveyed by the blower is smoke,no more than 250ºC of the highest temperature.
A dust catching device must be installed in front of the blower,to reduce as much as possible the dust in the smoke entered the blower.The dust catching efficiency is no less than 85%.
Performance indicated in the performance chart,the performance of ventilator is calculated according to the air medium that:ventilator t=20ºC,atmospheric pressure pa=101325pa,air density ρ=1.2kg/m3.The performance of blower is calculated according to the air medium that:air temperature t=140ºC,atmospheric pressure Pa=101325Pa,air density ρ=0.85kg/m3.
- Model G4-73-11 and Y4-73-11 boiler ventilator and blower apply to the system of ventilator and blower for vapor boiler below 2~670T/H in the power plant.While having no special requirement,G4-73-11 may also be used for mine ventilation and ordinary ventilation.
The medium conveyed by the ventilator is air,no more than 80ºC of the highest temperature.The medium conveyed by the blower is smoke,no more than 250ºC of the highest temperature.
A dust catching device must be installed in front of the blower,to reduce as much as possible the dust in the smoke entered the blower.The dust catching efficiency is no less than 85%.
Performance indicated in the performance chart,the performance of ventilator is calculated according to the air medium that:ventilator t=20ºC,atmospheric pressure pa=101325pa,air density ρ=1.2kg/m3.The performance of blower is calculated according to the air medium that:air temperature t=200ºC,atmospheric pressure Pa=101325Pa,air density ρ=0.745kg/m3.
- Y5-48 series centrifugal boiler blower is designed for the industrial boiler of 1-20T/H which is fit for various burning medium and equipped with smoke and dust catching device,which may be selected by those with certain absorption condition and applicable performance.No more than 250ºC of the highest temperature.Add the dust catching device of no less than 85% dust catching efficiency in front of the blower,so as to reduce the smoke content entered the blower,and increase the blower's longevity.The blower's performance is indicated with the specifications of wind volume,full pressure,rotating speed of the principal axis,axis power,efficiency,etc.Among the performance shown in the performance chart,NO.4-6.3,the performance of blower is calculated according to the air medium that:air temperature t=200ºC,atmospheric pressure P0=101300Pa,air density ρ=0.745kg/m3,above NO.8,is calculated according to that:air temperature t=140ºC,atmospheric pressure P0=101300Pa,smoke density ρ=0.85kg/m3.
This series of blowers use jib-headed strap transmission(C type)
This model of blower is single inhalation,6 types:NO.4,5,6.3,8,10,12.5,each may be made in the model of left revolving or right revolving.
For the convenience of customer's installation and debug,the unitary bracket and shock absorption bracket.
- Y9-39, Y8-39 model of blower applies to the blow system of 1-35T/h.The medium conveyed by the blower in smoke.No more than 250ºC of the highest temperature. Add the dust catching device in front of the blower,so as to reduce the smoke content entered the blower.Normally,the dust catching efficiency is no less than 85%.This model of blower is single inhalation,13 types:NO,4,4.5,5,5.6,6.3,7.1,8,9,10,11.2,12.5,14,16,all in direct joint transmission(D type transmission)
Each may be made in the model of left revolving or right revolving.
For the convenience of customer's installation and debug,the unitary bracket and shock absorption bracket
- Model YX9-35 5C,6.3C,8C\D are developed to apply to the boiler of 1t,2t or 4t,which may be selected by those with certain absorption condition and applic able performance.No more than 250ºC of the highest temper ature.Add the dust catching device of no less than 85% dust catching efficiency in front of the blower,so as to reduce the smoke content entered the blower,and increase the blower's longevity.
The blower's performance is indicated with the specifications of wind volume,full pressure,rotating speed of the principal axis,axis power,efficiency,etc.Among the performance shown in the performance chart,the performance of blower is calculated according to the air medium that:air temperature t=200ºC,atmospheric pressure P0=101325Pa,air density ρ=0.745kg/m3
This model of blower is single inhalation,3 types:NO.5,6.3,8
Each may be made in the model of left revolving or right revolving.For the convenience of customer's installation and debug,the unitary bracket and shock absorption bracket.
No. |
Type |
r/min |
No. |
Capacity m3/h |
Pa |
(kW) |
motor |
×× size L×W×H mm |
|
Type |
power kW |
||||||||
2 | A | 2900 | 1 | 483 | 481 | 0.15 | Y80S-2 | 0.75 | 400×414×200 |
2 | 890 | 294 | 0.18 | ||||||
2.8 | A | 2900 | 1 | 1130 | 994 | 0.67 | Y90S-2 | 1.5 | 492×577×570 |
2 | 1310 | 966 | 0.72 | ||||||
3 | 1480 | 933 | 0.71 | ||||||
4 | 1659 | 887 | 0.74 | ||||||
5 | 1828 | 835 | 0.77 | ||||||
6 | 2007 | 770 | 0.79 | ||||||
7 | 2177 | 702 | 0.81 | ||||||
8 | 2356 | 606 | 0.80 | ||||||
3 | A | 2900 | 1 | 1588 | 1142 | 0.96 | Y90S-2 | 1.5 | 492×577×570 |
2 | 1797 | 1124 | 1.03 | ||||||
3 | 2005 | 1097 | 1.08 | ||||||
4 | 2214 | 1057 | 1.12 | ||||||
5 | 2423 | 994 | 1.14 | ||||||
6 | 2631 | 924 | 1.17 | ||||||
7 | 2840 | 829 | 1.18 | ||||||
8 | 3049 | 716 | 1.16 | ||||||
3 | A | 1450 | 1 | 794 | 285 | 0.13 | Y80S-4 | 0.75 | 492×577×570 |
2 | 898 | 280 | 0.14 | ||||||
3 | 1003 | 273 | 0.14 | ||||||
4 | 1107 | 263 | 0.15 | ||||||
5 | 1211 | 248 | 0.16 | ||||||
6 | 1316 | 230 | 0.16 | ||||||
7 | 1420 | 207 | 0.16 | ||||||
8 | 1524 | 179 | 0.16 | ||||||
3.2 | A | 2900 | 1 | 1688 | 1300 | 1.23 | Y90L-2 | 2.2 | 526×649×596 |
2 | 1955 | 1263 | 1.31 | ||||||
3 | 2209 | 1220 | 1.38 | ||||||
4 | 2476 | 1160 | 1.34 | ||||||
5 | 2729 | 1091 | 1.39 | ||||||
6 | 2996 | 1006 | 1.43 | ||||||
7 | 3250 | 918 | 1.47 | ||||||
8 | 3517 | 792 | 1.45 |